AxxonSoft Configuration and Operation Manual for the Rosslare Integration Module Version 1.0 Moscow, 2011
10 To configure АС-215 controller entrances do the following: 1. Go to the setting panel of the Rosslare entrance object (Figure 3.5-2). Figure 3.
11 Figure 3.5-3 Creation of the Rosslare exit object To configure АС-215 controller exits do the following: 1. Go to the setting panel of the Ross
12 3.5.3 Configuration of doors Configuration of АС-215 controller doors is performed on the setting panel of the Door object. This object is creat
13 Figure 3.5-6 Setting panel of the Door object 2. From the Number dropdown list select the door address (Figure 3.5-6, 1). 3. From the Authori
14 Configuration of doors is completed. 3.5.4 Configuration of readers АС-215 controller can service no more than two readers. Note. One can creat
15 Figure 3.5-8 Setting panel of the Reader object 2. From the Number dropdown list select the corresponding reader (Figure 3.5-8, 1). 3. For re
16 11. From the Time zone dropdown list select the time zone for double pass control (Figure 3.5-8, 10). 12. From the Antipassback dropdown list se
17 Figure 3.5-10 Setting panel of the Events connection object 2. From the Source type dropdown list select the type of events source-object (Fig
18 Figure 3.6-1 Setting panel of the Siren object To configure AC-215 controller siren do the following: 1. Go to the setting panel of the Siren
19 3.7 Configuration of user settings To configure user settings do the following: 1. Go to the setting panel of the Rosslare object (Figure 3.7-
2 Contents CONTENTS ...
20 4. To restrict user facilities set the corresponding checkbox in the Restricted facilities column (Figure 3.7-2, 5). 5. To give user the privile
21 5. To send changes of users, time zones and access levels to Rosslare devices set the Users dynamic recording checkbox (Figure 3.8-1, 4). 6. To
22 4 Operation of the Rosslare integration module 4.1 General information on operation of the Rosslare module The following interface objects are
23 Figure 4.4-1 Feature menu of the Rosslare exit object Table 4.4-1 Description of feature menu of the Exit object Command Feature Close exit Clo
3 1 List of terms Access control system (ACS) is a hardware-software complex for carrying out access control functions. Rosslare ACS integrated sys
4 2 Introduction 2.1 Purpose of document Configuration and operation manual for the Rosslare integration module is an informational reference man
5 3 Configuration of Rosslare integration module 3.1 Procedure for configuring of Rosslare integration module Rosslare ACS integration module is
6 Figure 3.3-1 The Connection object There are two ways of Rosslare connection with Intellect Server: 1. Through COM–port; 2. Through TCP/IP. 3.
7 3. In the Period for re-connecting (min) field using up-down keys set the time (in minutes) during which the attempts to re-connect with Intellect
8 Figure 3.4-1 The АС−215 controller object To configure АС−215 controller do the following: 1. Go to the setting panel of the АС−215 controller
9 7. From the Antipassback dropdown list select the control mode of double pass through the readers (Figure 3.4-2, 6). Table 3.4-1 Description of p
Comentarios a estos manuales