Hardware Installation and User’s Guide
AC-020
03/02
Vista de pagina 0
1 2 3 4 5 6 ... 69 70

Indice de contenidos

Pagina 1 - 03/02

0852146397#DOOR 1DOOR 2 Hardware Installation and User’s GuideAC-020 03/02

Pagina 2 - Page 2 03/02

AC-020 Page 10 03/02

Pagina 3 - Access Control System

AC-020 Page 11 03/02 Introduction The AC-020 is an advanced two door controller, which allows you to add or delete employees from the system, change s

Pagina 4 - Copyright

AC-020 Page 12 03/02 enclosed for your reference to assist you with your record keeping. The AC-020 is capable of learning both PIN codes (keyboard ba

Pagina 5 - AC-020 Page 5 03/02

AC-020 Page 13 03/02 Key Features Here are some of the AC-020 system key features: • Supports two 26-Bit Wiegand compatible Readers • Three Modes of

Pagina 6 - AC-020 Page 6 03/02

AC-020 Page 14 03/02 Technical Specifications Electrical Characteristics Main Unit Operating Voltage: 16V AC (1.5A, 25VA) From a transformer Maximum I

Pagina 7 - AC-020 Page 7 03/02

AC-020 Page 15 03/02 Inputs Request to Exit (REX): N.O. Dry Contact Reader Input: 26-Bit Wiegand Compatible Indicators & Annunciators Visual: Two

Pagina 8 - AC-020 Page 8 03/02

AC-020 Page 16 03/02 Installation The AC-020 has been designed for easy installation. Only a few steps are required to install the controller. In this

Pagina 9 - AC-020 Page 9 03/02

AC-020 Page 17 03/02 Mounting the Controller 1) Before starting, select the location for mounting the AC-020 controller. The controller should be ins

Pagina 10 - Page 10 03/02

4) Remove the case screw from the controller (see diagram below to locate the case screw) and remove the front case from the controller. 5) Mount th

Pagina 11 - Introduction

Power Wiring 0852146397#DOOR 1DOOR 2POWER SUPPLYFROMTRANSFORMER16V AC (1.5A, 25VA)(+)(-)12V DC LEAD ACIDBATTERYUP TO 7 AHRECOMMENDED(+)(-) Typical Lo

Pagina 13 - Key Features

Reader Wiring 0852146397#DOOR 1 DOOR 2READERREADER+12V(-)DOD1+12V(-)DOD1(-)DOD112V DC, Max. 300mA12V DC, Max. 300mADOOR 1DOOR 2(-)+12VDOD1+12V AC-020

Pagina 14 - Technical Specifications

AC-020 Page 21 03/02 Features and Concepts Now that you have installed your AC-020 controller, it is time to become familiar with its features and con

Pagina 15 - Mechanical Characteristics

Modes of Operation IMPORTANT NOTE: • In all of the following operations, in order to select DOOR 1 press the * key. In order to select DOOR 2 press t

Pagina 16 - Installation

• The Lock Strike will remain active according to the programmed Release Time. • In addition, it is possible to activate the Lock Strike in the foll

Pagina 17 - Mounting the Controller

3) Secure Mode • The DOOR 1 / DOOR 2 LED is red DOOR 1 DOOR 2RED • In this mode the Controller is in the highest level of security. • The Controlle

Pagina 18 - AC-020 Page 18 03/02

Changing the Modes of Operation NOTE: Changing the modes of operation can be done by entering the correct code into the Controller’s Programming keypa

Pagina 19 - Power Wiring

Changing from Secure Mode to Normal Mode 1) The controller is in Secure Mode • DOOR 1 / DOOR 2 LED is red DOOR 1 DOOR 2RED 2) Enter your Normal /

Pagina 20 - Reader Wiring

3) Press the “*/#” key, respectively. • DOOR 1 / DOOR 2 LED will turn orange DOOR 1DOOR 2ORANGE • You are now in Bypass Mode Changing from Bypass

Pagina 21 - Features and Concepts

AC-020 Page 28 03/02 Events and Event Actions Tamper Event A Tamper Event is triggered if the controller detects that a reader has been disconnected o

Pagina 22 - Modes of Operation

AC-020 Page 29 03/02 Request to Exit (REX) Button The REX button must be located inside the premises to be secured and is used to open the door withou

Pagina 23 - AC-020 Page 23 03/02

AC-020 Page 3 03/02 Hardware Installationand User’s Guide for the AC-020Access Control System 0852146397#DOOR 1DOOR 2

Pagina 24 - DOOR 1 DOOR 2

AC-020 Page 30 03/02 Siren Sound Siren sound triggered by Door 1 or Door 2 tamper is generally stopped by clearing the tamper of that door. However, i

Pagina 25 - Secure Mode

AC-020 Page 31 03/02 Programming Instructions After reading Features and Concepts – page 21, you should already have an understanding of the AC-020’s

Pagina 26 - Bypass Mode

AC-020 Page 32 03/02 Programming Menu Quick Reference Guide Menu Number Menu Description Page Number 1 Changing Lock Strike Code 1 38 2 Changing Loc

Pagina 27 - Changing from Bypass Mode to

AC-020 Page 33 03/02 Programming the AC-020 FOR DOOR 1 PROGRAM: Menu Number Function Initial Setting 1 Changing Lock Strike Code 1 2580 2 Changing L

Pagina 28 - Events and Event Actions

AC-020 Page 34 03/02 FOR DOOR 2 PROGRAM: Menu Number Function Initial Setting 1 Changing Lock Strike Code 1 0852 2 Changing Lock Strike Code 2 0000*

Pagina 29 - Request to Exit (REX) Button

AC-020 Page 35 03/02 NOTE: You must be in NORMAL mode to program the AC-020. DOOR 1 / DOOR 2 LED will be green. Wrong or timed out entries will reset

Pagina 30 - Siren Sound

Entering Programming Mode To begin programming the controller’s settings, the AC-020 must first place into Programming Mode. You may only enter Progra

Pagina 31 - Programming Instructions

AC-020 Page 37 03/02 Exiting Programming Mode 1) To exit Programming Mode at any time: Press the “*” or “#” key for 2 seconds. You will hear 3 beeps

Pagina 32 - Reference Guide

Changing Lock Strike Code 1 1) Press the “*/#” key for 2 seconds • You will hear a short beep • The DOOR 2 LED will turn off • The DOOR 1 LED will

Pagina 33 - Programming the AC-020

4) Enter the new 4-digit code you wish to set as Lock Strike Code 1. ? ???• You will hear 3 beeps • The system will return to NORMAL mode AC-020 P

Pagina 34 - FOR DOOR 2 PROGRAM:

AC-020 Page 4 03/02 Copyright Information in this document, including URL and other Internet Web site references, is subject to change without notice.

Pagina 35 - AC-020 Page 35 03/02

Changing Lock Strike Code 2 1) Press the “*/#” key for 2 seconds • You will hear a short beep • The DOOR 2 LED will turn off • The DOOR 1 LED will

Pagina 36 - Entering Programming Mode

4) Enter the new 4-digit code you wish to set as the new Programming Code. ? ???• You will hear 3 beeps • The system will return to Normal mode AC-

Pagina 37 - Exiting Programming Mode

Changing the Programming Code 1) Press the “*/#” key for 2 seconds • You will hear a short beep • The DOOR 2 LED will turn off • The DOOR 1 LED wi

Pagina 38 - Changing Lock Strike Code 1

4) Enter the new 4-digit code you wish to set as the new Programming Code ? ???AC-020 Page 43 03/02 NOTE: Programming Code cannot be erased. When t

Pagina 39 - AC-020 Page 39 03/02

Changing the Normal / Secure Code 1) Press the “*/#” key for 2 seconds • You will hear a short beep • The DOOR 2 LED will turn off • The DOOR 1 LE

Pagina 40 - Changing Lock Strike Code 2

4) Enter the new 4-digit code you wish to set as the new Normal/Secure change code. ? ???• You will hear 3 beeps AC-020 Page 45 03/02 • The system

Pagina 41 - AC-020 Page 41 03/02

Changing the Normal / Bypass Code 1) Press the “*/#” key for 2 seconds • You will hear a short beep • The DOOR 2 LED will turn off • The DOOR 1 LE

Pagina 42

AC-020 Page 47 03/02 Option 1: Disabling Bypass Mode - Disabling the Chime • Enter 0000. The Bypass Mode and the Chime function are disabled. • You

Pagina 43 - AC-020 Page 43 03/02

AC-020 Page 48 03/02 Option 4: Enabling Bypass Mode - Enabling the Chime • Enter a 4-digit code ending with any digit except 0. The Bypass mode and t

Pagina 44 - Changing the Normal / Secure

Changing the Door Release Time 1) Press the “*/#” key for 2 seconds • You will hear a short beep • The DOOR 2 LED will turn off • The DOOR 1 LED w

Pagina 45 - AC-020 Page 45 03/02

AC-020 Page 5 03/02 package with your payment receipt to your point of purchase for a full refund. Grant of License. Rosslare and its suppliers grant

Pagina 46 - Changing the Normal / Bypass

AC-020 Page 50 03/02 NOTE: This is a 4-digit code. The first digit signifies whether the unit is being used for fail secure (factory default setting)

Pagina 47 - AC-020 Page 47 03/02

Enrolling Proximity Cards/Pin Codes into the System NOTE: Each proximity card is unique and can only be assigned to one slot at a time. If an unassig

Pagina 48 - AC-020 Page 48 03/02

3) Press 7 • The DOOR 2 LED will turn green • The DOOR 1 LED will turn orange GREEN 1DOOR 2ORANGEDOOR 4) Enter the 3-digit slot code you wish to a

Pagina 49

AC-020 Page 53 03/02 7) Present the proximity card designated for this slot number to the reader. • The DOOR 2 LED will stop flashing OR, • Enter t

Pagina 50 - AC-020 Page 50 03/02

Deleting Proximity Cards/Pin Codes from the System 1) Press the “*/#” key for 2 seconds • You will hear a short beep • The DOOR 2 LED will turn off

Pagina 51 - Codes into the System

4) Enter the 3-digit slot code you wish to delete from the system • The DOOR 2 LED will flash red DOOR 1ORANGDOOR 2E RED 5) Enter the 4-digit Pro

Pagina 52 - AC-020 Page 52 03/02

Return to Factory Default Settings 1) Press the “*/#” key for 2 seconds • You will hear a short beep • The DOOR 2 LED will turn off • The DOOR 1 L

Pagina 53 - AC-020 Page 53 03/02

4) Enter the 4-digit Programming Code. (This last step confirms that you intentionally want to delete all your initial settings and employees from th

Pagina 54 - Codes from the System

AC-020 Page 58 03/02 Replacing a Lost Programming Code In the event that your Programming Code is lost, complete the following procedure to enter Prog

Pagina 55 - AC-020 Page 55 03/02

AC-020 Page 59 03/02 Replacing a Lost Normal / Secure Code In the event that your Normal / Secure Code is lost and you are locked in Secure Mode, comp

Pagina 56 - AC-020 Page 56 03/02

AC-020 Page 6 03/02 Agreement, rights to use the Software shall automatically terminate and the Software must be returned to Rosslare or all copies of

Pagina 57 - AC-020 Page 57 03/02

Accessories Wiegand 26 Integrated Door Controllers AC-020 Page 60 03/02 AY-X09 Series PIN Readers AY-C09 / AY-D09 • For indoor use • Slim Stylish

Pagina 58 - Replacing a Lost Programming

AY-X11 Series Prox Readers w/ Bell AY-C11 / AY-D11 • Reading Distance: 8 to 10cm • RF Modulation: ASK at 125 kHz • For indoor use • Slim Stylish

Pagina 59 - AC-020 Page 59 03/02

AY-X12 Series Prox Readers AY-C11 / AY-D11 • Reading Distance: 8 to 10cm • RF Modulation: ASK at 125 kHz • For indoor use • Slim Stylish Design

Pagina 60 - Accessories

AY-X12 Series Prox Readers AY-H12 / AY-J12 / AY-K12 / AY-L12 / AY-M12 • Reading Distance: 7 to 12cm • RF Modulation: ASK at 125 kHz • For outdoor

Pagina 61 - Prox Readers

AY-X19 Series Pin & Prox Readers AY-C19 / AY-D19 • Reading Distance: 8 to 10cm • RF Modulation: ASK at 125 kHz • For indoor use • Slim Stylis

Pagina 62 - AY-X12 Series

AC-020 Page 65 03/02 AY-L23 RF Reader AY-L23 • Read Range: 70 meters (200 feet) • For Outdoor Use (Water Proof) • Frequency: 433MHz • Slim Stylis

Pagina 64 - Readers

AC-020 Page 67 03/02 Technical Support International Web Site: http:///www.rosslare.com.hk/support/ Asia, Australia, & South America: Rosslare Ent

Pagina 67 - Technical Support

AC-020 Page 7 03/02 WARRANTIES. ROSSLARE EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABI

Pagina 68

9J-IDR-029 / 0706-0820029-00www.rosslare.com.hk9J-IDR-029 / 0706-0820029-00www.rosslare.com.hkwww.rosslare.com.hk

Pagina 69

AC-020 Page 8 03/02 apply. The above limitations will not apply in case of personal injury where and to the extent that applicable law requires such l

Pagina 70

AC-020 Page 9 03/02 Contents Introduction ..............11 Key Features ...........