Rosslare AC-C32 Especificaciones Pagina 18

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 42
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 17
Normal, Secure, and Master Users
18 AC-B/C/D3x Family Installation and Programming Manual
4. Normal, Secure, and Master Users
The controller accepts up to 500 users and provides entry via the use
of proximity cards and/or PIN codes. Each user is provided with two
code memory slots: Memory Slot 1 (Primary Code) and Memory Slot 2
(Secondary Code). For the AC-x32 models, the two memory slots can
be programmed for proximity cards, PIN codes, or a combination of
both proximity cards and PIN codes.
The way that the two memory slots are programmed determines a
user's access level and also determines the way that the unit grants
access in its three modes of operation.
There are three user levels:
Normal UserA Normal User only has a Primary Code and is only
granted access when the unit is in Normal or Bypass mode.
Secure UserA Secure User must have a Primary and Secondary
Code programmed; the two codes cannot be the same. The
Secure User can gain access when the unit is in any of its three
modes of operation. In Normal mode, the Secure User must use a
Primary Code to gain entry. In Secure Mode, the Secure User
must present both a Primary and Secondary Code to gain entry.
Master UserA Master User must have both Primary and
Secondary Codes programmed with the same PIN code. The
Master User can gain access during any mode of operation by
entering the PIN code. (The Master User is convenient, but is less
secure than a Secure User.)