Installation
14 AC-F/G4x Family Installation and Programming Manual
3. Installation
Installation of an RFID reader adjacent to metallic surfaces
might alter the reader’s specifications. To diminish this
interference, use a plastic spacer when mounting the reader.
3.1 Mounting Instructions
Prior to starting, select the location where the controller unit is to be
mounted.
To install the controller:
1. Open the controller by loosening and removing the case security
screw at the bottom using the security spline key.
2. Depending on the type of installation, gang box or panel mount,
drill the respective holes in the rear cover (Figure 3).
Figure 3: Drilling Holes Identification
The central hole is for routing the wiring to the controller.
3. Use the provided drilling template to accurately locate and drill
the required holes in the wall or panel.
4. Use the hardware provided to mount the back plate on the wall
or on a gang box. Be sure to route the wiring via the large center
hole in the back plate. Check for level.
5. Wire the controller's pre-wired cable as described in Section 3.2.