Rosslare AC-Q41H Manual de instrucciones Pagina 32

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 58
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 31
Programming
4.5 CHANGING THE NORMAL/SECURE CODE
Note:
When the auxiliary mode is 1, 2, 3 or 4, the auxiliary input takes
priority over the normal/secure code.
Wrong entries: you will hear a long beep and the controller will
return to its normal mode.
Code 0000 will erase and deactivate the normal/secure code.
1) Enter the programming mode.
Mode
Door
Green
2) Depress 4 to enter Menu 4.
The Mode indicator will flash red.
Mode Door
Red Green
3) Enter the new Normal/Secure code
4) ys ode.
.
S tem returns to its normal m
You will hear three beeps.
Mode
Door
Green
The Door indicator will turn off.
The Mode indicator will turn green.
4.6 CHANGING THE NORMAL/BYPASS CODE
The normal / bypass code is also used to turn the door chime off
and on. Chime only functions with the BL-D40 External Sounder.
Note:
The chime is only heard when the Lock Strike relay is activated
by a valid code entry.
a long beep and the controller will Wrong entries: you will hear
return to its normal mode.
Code 0000 will erase and deactivate the normal/bypass code.
1) nter the programming mode.
2)
The Mode indicator will flash orange.
E
Mode
Door
Green
Mode
Door
Depress 5 to enter Menu 5.
Orange
Green
Page 31 AC-Q4x Family, Installation and user Manual
Vista de pagina 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 57 58

Comentarios a estos manuales

Sin comentarios