Installation
20 HLX-40 Installer Manual
4.4.1 Wiring the HLX-40
Figure 6: Panel Wiring
Input Description
Siren
Relay output for external siren or strobe. Normally open
or normally closed for external siren contacts.
AUX 1
Programmable AUX outputs 1 and 2, 200 mA Sink
Current 12VDC open collector outputs Active Low.
AUX 2
GND
Ground
ZONE
Wired Zone (zone 40) Alarm input.
GND
Ground
TAMPER
Wired Zone (zone 40) Tamper input.
+15VDC VIN
Input voltage from AC/DC adaptor VIN = 13.815
GND
+13.8VDC
(-) AUX (OUT)
Auxiliary Power output (to power external devices) +13.8
VDC 500 mA Load current Max. Current limited.
LINE IN
Telephone line in (from the wall to the system).
HOME TEL
Telephone line out (from system to telephone device).
MD-62 Connection Socket
Connection Socket for 10 pin plug connecting panel to
PC with MD-62.
+BAT-
Battery Connector