This chapter discusses the AC-215 ACU input and output requirements.
Inputs
Release to Exit Button (REX)
REX enables quick exit from a premises. The following should be defined:
Single door controller: Door 1 - IN1
Double door controller:
Door 1 - IN 1
Door 2 - IN 2
Usually the REX input is connected to a push button that is located inside the premises. The
push button opens a door without reading a proximity card or PIN code.
Generally, the REX is located in a convenient position, for example, near Reception, and is
always set as enabled in the Veritrax AS-215 software.
Door Monitor
The Door Monitor connects to a door’s micro switch for door status monitoring. The following
should be defined:
Single door controller:
Door 1 - IN1A
Double door controller:
Door 1 - IN 1A
Door 2 - IN 2A
Two alarm states can be generated:
! Forced alarm- When the door is forcibily opened by unauthorized persons
! Door held open alarm- When the door is open for a period exceeding the lock strike
programmed open time
A Door held open alert can be generated by activating chime on speaker to remind that the
door should be close.
After the ACU enables access, the lock is activated according to its programmed time until one
of the following occurs:
! The ACU stops lock activation immediately after the door opens
! The ACU waits for the door to close. (This can help to reduce tailgating)
When the door open time period expires the ACU ends lock activation.