AC-215 Single and Double Door Access Control Unit
Hardware Installation Guide
21
Power Supply
The following diagram illustrates wiring between the PS-14 power supply and the AC215. It is
recommended to add a 12VDC lead acid backup battery to backup power if the main fails.
If the main output is 12VDC wire it to the (PS-14), otherwise support your power supply
according to output requirements.
For further information refer to the Output requirements page 7..
Reader
Proximity and keypad readers are supplied with a limited cable. The color of the cable
covering represents the cable’s function. .
!
When extending cable distance be careful with the color of the cable cover. The distance is
limited by the Wiegand standard.
~
VEN
~
16VAC
+VBAT
(+)
12UDC
(-)
1.5A
(-)12UDC
Tamper (-)
+
12VDC
(-)
0.5A
230/16
VAC
Back up
Battery
IN 1
+
-
Proximity Reader
READER 1
Purple
Brown
White
Green
Black
Red