AC-215 Single and Double Door Access Control Unit
Hardware Installation Guide
5
T
T
e
e
c
c
h
h
n
n
i
i
c
c
a
a
l
l
S
S
p
p
e
e
c
c
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
This chapter discusses the technical specification required for the system.
Electrical Specifications
Main Unit
Operating Voltage:
12V DC 0.5A
From PS-14
Maximum Input Current:
(Not including attached devices)
Standby: 125mA
Maximum: 325mA
Outputs
Relay Outputs:
5A Relay N.O. and N.C. options
Inputs
General Inputs:
High impedance active low inputs. Maximum voltage:
5V DC
Reader's Electrical
requirements:
Voltage: 12V DC
Max Current: 300mA
Indicators and Annunciators
Visual:
8 LEDs
Audio: Built in sounder (Bell, Chime and Siren)
Speaker's Electrical
Characteristics:
8 ohm, 750mW