Fel! Formatmallen är inte definierad.
AS-215 PC management software
Page 15
Step 1 - Defining a Network
This step connects the hardware to the PC.
To add a network:
1. In the Tree pane right-click on Networks and click the 'New' button to
open a new Network dialog box.
This dialog box is dynamic and has the following fields:
Field Sub-field
Description
Description
Network name
This selection must match the dipswitch definitions.
There are four options:
Inactive
If this option is selected the network is inactive and only the
Description and this field are available
Serial
This option is the default. It opens the Serial Network fields:
COM Port – where up to eight ports can be defined
Speed – which can be 9600, 19200, 38400 or 57600
TCP/IP
This option opens the TCP/IP network fields:
Type – choose between Remote (WAN) and Local (LAN). If LAN
was selected press Configuration
, if WAN was selected set the IP
address, Port number and serial speed.
IP Address of the Host LAN Module (view only).
Port Number of the Host LAN Module (view only).
Speed – set the serial baud rate to 9600, 19200, 38400 or 57600
Configuration – Defines and transfers the network and serial
parameters to the Host LAN Module using Rosslare’s MD-N32.
Network type
Modem
This option opens the following fields:
COM Port – where up to eight ports can be defined
Speed – which can be 9600, 19200, 38400 or 57600
Configuration – Defines the phone Number (where the ACU is
located), password, dialing schedule and initialization
conditions to the Host Modem.