Input and Output Requirements
Door Monitor Input
The Door Monitor Input typically connects to a Normally Closed
door sensing micro-switch for door status monitoring. The
following should be defined:
Single door controller: Door 1 - IN1A
Double door controller: Door 1 - IN 1A
Door 2 - IN 2A
The panel can generate two warning conditions:
Forced alarm: When the door is forcibly opened by
unauthorized persons
Door held open alarm: When the door is open for a period
exceeding the lock strike programmed open time
Note:
Warning conditions are governed by the software set-up.
See the "VeriTrax Access Control System User Guide" for
more details.
After the access control panel enables access, the lock is
activated according to its programmed time until one of the
following occurs:
The access control panel stops lock activation
immediately after the door opens
The access control panel waits for the door to close (this
can help to reduce tailgating)
Note:
Lock activation is governed by the software set-up. See
the "VeriTrax Access Control System User Guide" for more
details.
When the door open time period is over, the access control
panel ends lock activation.