Input and Output Requirements
General Purpose Inputs
These are free inputs that can be used for various functions.
The following should be defined:
Single door controller: Door 1 – IN 2
Door 1 – IN 2A
Double door controller: (no general purpose
inputs available)
General purpose inputs are suitable for most uses. For example,
they might be used to detect tampering, to activate alarm
sensors or for monitoring power supply failure.
General purpose inputs are activated when the panel is
opened.
Note:
When fitting the AC-225U, the internal tamper switch must
be connected to a UL Listed burglary unit.
Refer to the UL Listed burglary unit for connection
instructions.
4.3 Outputs
Rosslare Security recommends the use of suppression diodes
for all outputs that will be connected to inductive loads and
activated by DC current, such as Magnetic Lock ("Maglock")
or door strike devices.
Each suppression diode should be connected near its
inductive load. Be careful to attach the diode's cathode to be
tied to the +V terminal of the load. Attach the diode's anode
to the –V terminal.
Door Lock
There are two types of door locking devices:
• Fail open (fail secure)
• Fail close (fail safe)