AC-225 Hardware Settings
AC-225 Hardware Installation and User Guide Page 27
5. AC-225 Hardware Settings
Each AC-225 panel controls an entrance. The behavior of the
panel is controlled by DIP switch settings.
Select the appropriate DIP switch setting to operate the panel
as either a single or double door. See below
Access Control Panel Type, page 29.
Access control panels configured as single door controllers
have two readers, IN or OUT.
Outputs Door Lock output (OUT 1)
General purpose output (OUT 1A)
General purpose output (OUT 2)
General purpose output (OUT 2A)
Inputs Request to exit (IN 1)
Door monitor input (IN 1A)
General purpose input (IN 2)
General purpose input (IN 2A)
Access control panels configured as double door controller
have two readers, IN or OUT.
Outputs Lock output for Door 1 (OUT 1)
General purpose output (OUT 1A)
Lock output for Door 2 (OUT 2)
General purpose output (OUT 2A)
Inputs Request to exit for Door1 (IN 1)
Monitor input for Door 1 (IN 1A)
Request to exit for Door2 (IN 2)
Monitor input for Door 2 (IN 2A)